Register    Login    Forum    Search    FAQ

Board index » Programming Alarm Modems » PLC connectivity




Post new topic Reply to topic  [ 21 posts ]  Go to page Previous  1, 2
Author Message
 Post subject:
 Post Posted: Tue Apr 22, 2008 2:26 pm 
Offline
Newbee

Joined: Fri Apr 18, 2008 9:55 pm
Posts: 10
Tixi-Support wrote:
MainaE wrote:
I do have a serial port password but TILA has no option for this.

That's not supported. You'll have to remove the serial password, but you can keep the program password.

I think it was a mistake my password is program password not serial port password.
Did you mean to add PLC variables via Data logging ->Event -> variable or Dispatch->Variable?


Top 
 Profile  
Reply with quote  
 Post subject:
 Post Posted: Tue Apr 22, 2008 2:49 pm 
Offline
Tixi-Support-Team

Joined: Mon Oct 10, 2005 1:40 pm
Posts: 94
Location: Berlin
MainaE wrote:
Did you mean to add PLC variables via Data logging ->Event -> variable or Dispatch->Variable?

I mean the module "Variables" (next to PLC), option "new variable".

_________________
Tixi Support Team

E-Mail-Support, Mo-Fr, 9:00am - 5:00pm, Tixi-Support@tixi.com
Support-Hotline, Mo-Fr, 9:00am - 5:00pm, +49-30-406 08 300


Top 
 Profile  
Reply with quote  
 Post subject:
 Post Posted: Tue Apr 22, 2008 7:33 pm 
Offline
Newbee

Joined: Fri Apr 18, 2008 9:55 pm
Posts: 10
Tixi-Support wrote:
MainaE wrote:
Did you mean to add PLC variables via Data logging ->Event -> variable or Dispatch->Variable?

I mean the module "Variables" (next to PLC), option "new variable".


got a new\ problem. I a did reset the TAM via TILA and after the LEDs brinked they never stopped.I switched off power and after powering up no changes.
Currently the Data out LED blinks twice then process+Line+Dataout +Modem flashes once then cycle repeats endlessly.
Currently no connection to the modem via serial port is possible.

Any idea on how to escape from here?


Top 
 Profile  
Reply with quote  
 Post subject:
 Post Posted: Wed Apr 23, 2008 7:56 am 
Offline
Tixi-Support-Team

Joined: Mon Oct 10, 2005 1:40 pm
Posts: 94
Location: Berlin
MainaE wrote:
out LED blinks twice then process+Line+Dataout +Modem flashes once then cycle repeats endlessly.
Currently no connection to the modem via serial port is possible.
Any idea on how to escape from here?

Try a hardware factory reset. See chapter 12.2.3 of HG-Manual.
If the problem still occurs -> hardware failure

_________________
Tixi Support Team

E-Mail-Support, Mo-Fr, 9:00am - 5:00pm, Tixi-Support@tixi.com
Support-Hotline, Mo-Fr, 9:00am - 5:00pm, +49-30-406 08 300


Top 
 Profile  
Reply with quote  
 Post subject:
 Post Posted: Wed Apr 23, 2008 8:38 am 
Offline
Newbee

Joined: Fri Apr 18, 2008 9:55 pm
Posts: 10
Tixi-Support wrote:
MainaE wrote:
out LED blinks twice then process+Line+Dataout +Modem flashes once then cycle repeats endlessly.
Currently no connection to the modem via serial port is possible.
Any idea on how to escape from here?

Try a hardware factory reset. See chapter 12.2.3 of HG-Manual.
If the problem still occurs -> hardware failure


no change after factory reset


Top 
 Profile  
Reply with quote  
 Post subject:
 Post Posted: Wed Apr 23, 2008 10:19 am 
Offline
Tixi-Support-Team

Joined: Mon Oct 10, 2005 1:40 pm
Posts: 94
Location: Berlin
MainaE wrote:
no change after factory reset

Please contact our support team via email for RMA process.

_________________
Tixi Support Team

E-Mail-Support, Mo-Fr, 9:00am - 5:00pm, Tixi-Support@tixi.com
Support-Hotline, Mo-Fr, 9:00am - 5:00pm, +49-30-406 08 300


Top 
 Profile  
Reply with quote  
Display posts from previous:  Sort by  
 
Post new topic Reply to topic  [ 21 posts ]  Go to page Previous  1, 2

Board index » Programming Alarm Modems » PLC connectivity


Who is online

Users browsing this forum: No registered users and 4 guests

 
 

 
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
cron